ACROSS THE WORLD, ALUCOBOND® A2 is the only non-combustible aluminum composite panel used in architecture.
Due to its non-combustible core, this fantastic product meets stringent fire regulations and hugely increases the possibilities when it comes to creative building design.
As with all ALUCOBOND® products, ALUCOBOND® A2 allows for simple processing, is impact-resistant, break-proof, and weatherproof – and above all non-combustible.
THICKNESS | STANDARDS | UNIT | 3MM | 4MM | |
---|---|---|---|---|---|
Thickness of Aluminium Layers | [mm] | 0.5 | 0.5 | ||
Weight | [kg/m²] | 5.9 | 7.6 | ||
Width | [mm] | 1250 / 1500 | 1250 / 1500 |
TECHNICAL PROPERTIES | STANDARDS | UNIT | 3MM | 4MM | |
---|---|---|---|---|---|
Section modulus | W | DIN 53293 | [cm³/m] | 1.25 | 1.75 |
Rigidity | E·J | DIN 53293 | [kNcm²/m] | 1250 | 2400 |
Alloy / Temper of Aluminium Layers | EN 573-3 / EN 515 | EN AW 5005A (AIMg1) H22/H42 | EN AW 5005A (AIMg1) H22/H42 | ||
Modulus of Elasticity | EN 1999 1-1 | [N/mm²] | 70.000 | 70.000 | |
Tensile Strength of Aluminium | EN 485-2 | [N/mm²] | Rm ≥ 130 | Rm ≥ 130 | |
0.2 % Proof Stress | EN 485-2 | [N/mm²] | Rp0,2 ≥ 90 | Rp0,2 ≥ 90 | |
Elongation | EN 485-2 | [%] | A50 ≥ 5 | A50 ≥ 5 | |
Linear Thermal Expansion | EN 1999 1-1 | 2.4 mm/m at 100ºC temperature difference | 2.4 mm/m at 100ºC temperature difference |
CORE | STANDARDS | UNIT | 3MM | 4MM | |
---|---|---|---|---|---|
Mineral compound, polymer bonded |
SURFACE | STANDARDS | UNIT | 3MM | 4MM | |
---|---|---|---|---|---|
Lacquering | Coil Coating Fluorocarbon based (e.g. PVDF) | Coil Coating Fluorocarbon based (e.g. PVDF) | |||
Gloss (initial value) | EN 13523-2 | [%] | 30-80 | 30-80 | |
Pencil Hardness | EN 13523-4 | HB-F | HB-F |
ACOUSTICAL PROPERTIES | STANDARDS | UNIT | 3MM | 4MM | |
---|---|---|---|---|---|
Sound Absorption Factor | αs | ISO 354 | 0.5 | 0.5 | |
Sound Transmission Loss | Rw | ISO/DIS 717-1, EN ISO 140-3 | [dB] | 27 | 27 |
Loss Factor | d | EN ISO 6721 Frequency range 100-3200 Hz | 0.004 | 0.005 |
THERMAL | STANDARDS | UNIT | 3MM | 4MM | |
---|---|---|---|---|---|
Thermal Resistance | R | DIN 52612 | [m²K/W] | 0.002 | 0.002 |
Thermal conductivity | λ | DIN 52612 | [W/mK] | 1.99 | 1.77 |
Heat Transition Coefficient | U | DIN 52612 | [W/m²K] | 5.83 | 5.80 |
Temperature Resistance | [ºC] | -50 to +80 | -50 to +80 |
Wind load and permissible panel sizes
ALUCOBOND® A2 3 mm
ALUCOBOND® A2 4 mm
The graphs for 3 mm and 4 mm thick ALUCOBOND® A2 indicate the maximum permissible panel length (σ = 53 N/mm²) (without having to add a stiffener) based in applicable design wind load and panel width. Values apply to 4-side supported panels. Values for other systems on request.